Home / Products / INRT Cross Reference
INRT Cross Reference & Performance Comparison
Twenty commonly used INRT models, compared item-by-item against established imported equivalents at identical package size and inductance. Parameters compared: DC resistance (DCR), saturation current (Isat) and temperature-rise current (Irms, ΔT = 40℃).
20
Models compared
48
Parameters ahead
6
Case sizes covered
125
Models in full range
How to Read the Table
Advantage — INRT leads by more than 5%
Equivalent — within ±5%
Below — INRT trails by more than 5%
Measured Comparison — 20 INRT Models
Red indicates an INRT advantage of more than 5%. Lower DCR is better; higher Isat and Irms are better.
| L (μH) | INDA P/N | Imported Ref. (masked) | DCR Max INDA | DCR Max Ref | DCR Δ | Isat INDA | Isat Ref | Isat Δ | Irms INDA | Irms Ref | Irms Δ |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4.70 | INRT4030-4R7M-V | Xxx4030-4R7MEC | 33.50 | 44.10 | +24.0% | 5.2 | 4.6 | +13.0% | 6.6 | 5.1 | +29.4% |
| 6.80 | INRT4030-6R8M-V | Xxx4030-6R8MEC | 47.90 | 74.10 | +35.4% | 4.2 | 3.6 | +16.7% | 4.7 | 3.9 | +20.5% |
| 8.20 | INRT4040-8R2M-V | Xxx4040-8R2MEC | 44.30 | 66.90 | +33.8% | 4.3 | 4.0 | +7.5% | 5.4 | 3.4 | +58.8% |
| 10.00 | INRT4040-100M-V | Xxx4040-100MEC | 55.80 | 92.40 | +39.6% | 3.6 | 3.0 | +20.0% | 5.0 | 3.1 | +61.3% |
| 1.00 | INRT5030-1R0M-V | Xxx5030-1R0MEC | 5.80 | 9.40 | +38.3% | 14.0 | 8.7 | +60.9% | 17.8 | 11.1 | +60.4% |
| 2.20 | INRT5030-2R2M-V | Xxx5030-2R2MEC | 10.60 | 14.50 | +26.9% | 9.4 | 7.2 | +30.6% | 12.9 | 9.7 | +33.0% |
| 3.30 | INRT5030-3R3M-V | Xxx5030-3R3MEC | 14.90 | 23.30 | +36.1% | 8.4 | 5.9 | +42.4% | 10.0 | 8.1 | +23.5% |
| 4.70 | INRT5030-4R7M-V | Xxx5030-4R7MEC | 24.50 | 40.00 | +38.8% | 6.7 | 4.3 | +55.8% | 8.5 | 5.9 | +44.1% |
| 4.70 | INRT5050-4R7M-V | Xxx5050-4R7MEC | 16.00 | 24.20 | +33.9% | 7.0 | 6.6 | +6.1% | 9.7 | 8.2 | +18.3% |
| 5.60 | INRT5050-5R6M-V | Xxx5050-5R6MEC | 19.70 | 25.80 | +23.6% | 6.4 | 6.3 | +1.6% | 8.0 | 7.2 | +11.1% |
| 6.80 | INRT5050-6R8M-V | Xxx5050-6R8MEC | 23.10 | 29.50 | +21.7% | 6.2 | 6.0 | +3.3% | 7.5 | 6.4 | +17.2% |
| 8.20 | INRT5050-8R2M-V | Xxx5050-8R2MEC | 27.50 | 35.00 | +21.4% | 5.5 | 5.6 | −1.8% | 7.0 | 6.1 | +14.8% |
| 10.00 | INRT5050-100M-V | Xxx5050-100MEC | 33.60 | 45.00 | +25.3% | 4.9 | 4.9 | 0.0% | 6.2 | 4.9 | +26.5% |
| 15.00 | INRT5050-150M-V | Xxx5050-150MEC | 54.90 | 76.70 | +28.4% | 3.9 | 3.7 | +5.4% | 4.6 | 3.9 | +17.9% |
| 4.70 | INRT6060-4R7M-V | Xxx6060-4R7MEC | 13.20 | 14.40 | +8.3% | 14.0 | 10.5 | +33.3% | 12.0 | 11.0 | +9.1% |
| 5.60 | INRT6060-5R6M-V | Xxx6060-5R6MEC | 16.80 | 15.90 | −5.7% | 12.0 | 9.9 | +21.2% | 10.0 | 10.0 | 0.0% |
| 6.80 | INRT6060-6R8M-V | Xxx6060-6R8MEC | 18.90 | 20.80 | +9.1% | 10.0 | 9.2 | +8.7% | 8.2 | 9.0 | −8.9% |
| 10.00 | INRT6060-100M-V | Xxx6060-100MEC | 25.50 | 29.80 | +14.4% | 8.5 | 7.6 | +11.8% | 7.5 | 7.0 | +7.1% |
| 15.00 | INRT6060-150M-V | Xxx6060-150MEC | 44.00 | 43.80 | −0.5% | 6.6 | 5.8 | +13.8% | 6.0 | 6.0 | 0.0% |
| 22.00 | INRT6060-220M-V | Xxx6060-220MEC | 57.80 | 60.60 | +4.6% | 5.6 | 5.6 | 0.0% | 5.1 | 5.0 | +2.0% |
Test Conditions & Notes
- DCR measured at 25℃
- Isat at 10% inductance drop (ΔL/L₀ = −10%)
- Irms at ΔT = 40℃
- Imported reference part numbers are masked for compliance reasons
- Full 125-model comparison data and test reports available on request
Data reflects typical measured values. Design margins should always be validated on the final application board.
Let's Design the Right Inductor for Your Circuit